The GW-7243D is one of DeviceNet products in ICP DAS and it stands as a DeviceNet slave to Modbus TCP/RTU/ASCII master Gateway device. It allows a master located on a DeviceNet network to enter a dialogue with slave devices on the Modbus TCP/RTU/ASCII network. In DeviceNet network, it functions as a Group 2 Only Server device. In Modbus network, GW-7243D represents a master device and sends request message to access the Modbus TCP/RTU/ASCII slave device by DeviceNet object definition. In order to simplify the protocol converting mechanism, we also provide the GW-7243D Utility tool for users to configure the device parameters and build EDS file for the DeviceNet slave device. Users can easily apply Modbus TCP/RTU/ASCII devices in DeviceNet applications through the GW-7243D. The application architecture is depicted as following figure. Users can connect the Modbus TCP/RTU/ASCII devices to the DeviceNet network via the GW-7243D.
Applications:
Production cell builds and tests CPUs
Beer brewery
Equipment for food packing
Fiberglass twist machine
Sponge production plant
Sponge production plant
Overhead storage bin production
Pocket-bread bakery
Dinnerware production
HVAC module production
HVAC module production
Trawler automation system
LCD manufacturing plant
Rolling steel door production
Bottling line\
Tight manufacturing
Features:
DeviceNet Features
Comply with DeviceNet specification Volume I/II, Release 2.0
“Group 2 Only Server” DeviceNet subscriber
On-line change baud rate and MAC ID of CAN
MS.NS and IO Led indicators
Support Offline Connection Set and Device Shutdown Message
Connection supported:
one “Explicit Connection”
one “Polled Command/Response” connection
Modbus RTU Features
User can select the Modbus RTU/ASCII protocol for each COM port
Maximum support 10 Modbus RTU/ASCII commands for each COM port
Support Modbus function codes: 0x01,0x02,0x03,0x04,0x05,0x06,0x0F and 0x10
Support communication speed: 1200、2400、4800、9600、19200、38400、57600 and 115200 bps\
Data bits: 7 or 8 bits
Parity bits: None, even or odd
Stop bits: 1 or 2 bits
Maximum support 1920 channels DI/O for a Modbus RTU/ASCII command
Maximum support 120 channels AI/O for a Modbus RTU/ASCII command
Maximum support 2048 channels DI,2048 channels DO,1024 channels AI and 1024 channels AO for each COM port.
Modbus TCP Features
Maximum support 4 Modbus TCP devices
Maximum support 5 Modbus TCP commands for each Modbus TCP device
Support Modbus function codes: 0x01,0x02,0x03,0x04,0x05,0x06,0x0F and 0x10
Maximum support 1920 channels DI/O for a Modbus TCP command
Maximum support 120 channels AI/O for a Modbus TCP command
Maximum support 2048 channels DI,2048 channels DO,1024 channels AI and 1024 channels AO for each Modbus TCP device.
Utility: The GW-7243D Utility helps users to configure the devices, and has following features:
Support module IP/Gateway/Mask setting
Support DeviceNet node ID, baud rate setting
Support Com port communication setting
Support Modbus TCP/RTU/ASCII protocol communication parameters setting
Support DeviceNet Polling I/O connection path setting
Show Modbus TCP/RTU/ASCII protocol communication parameters
Show DeviceNet Application Objects configuration
Dynamic produce EDS file after setting
Product specification
Hardware
CPU
80186, 80 MHz or compatible
Watchdog
Watchdog IC
CAN Interface
Controller
NXP SJA1000T with 16 MHz clock
Transceiver
NXP 82C250
Connector
5-pin screwed terminal block (CAN_L, CAN_SHLD, CAN_H, N/A for others)