Tabelka poniżej prezentuje parametry techniczne urządzenia. W przypadku, gdyby prezentowane w niej informacje były niekompletne lub budziły wątpliwości prosimy o kontakt mailem bądź telefonicznie z naszym działem technicznym. Dodatkowo służymy pomocą w doborze właściwego urządzenia tak, aby optymalnie spełniało wymagania Państwa projektu.
Product specification
Power supply
Protection
Power reverse polarity protection
Input Range
10 ~ 30Vdc
Power Consumption
20 W (when I/O slots are empty )
General environment
temperatur
Operating: -25C ~ +75C , Storage : -30C ~ +80C
Humidity
5 ~ 90 % (non-condensing)
System
CPU
80188,40 MHz, or compatible
Watchdog timer
Yes
RTC (Real Time Clock)
Provide seconds, minutes, hours, day of week/month, month and year (1980 ~ 2079)
SRAM
512 KB
FLASH Memory
512 KB, Erase unit is 64K bytes, 100,000 erase/write cycles
NVRAM
31 bytes, battery backup, data valid up to 10 years
EEPROM
2048 bytes, retention 100 years. 1,000,000 erase/write cycles
SMMI
5-Digit 7-Seg. LED, four push buttons three LED on the front panel. It can display message, value, simulate input output.
I/O slots
4 empty slots for I-8417, 8 empty slots for I-8817. Accept parallel serial I/O boards
All remote I-7000 I-87K DI modules support counters. 100Hz max. value: 0 to 65535
High Speed Counter
I-87082: 100 kHz max. 32 bit I-8080: 450 kHz max. 32 bit
Protocols
Modbus Slave Protocol
COM1 COM2 default support Modbus RTU Slave protocol for connecting ISaGRAF, PC/HMI/OPC Server MMI panels.
Modbus Master Protocol
Up to 2 COM ports (COM1, 3, 4 or COM5 if multi-serial port boards are plugged) support Modbus master protocol to connect to other Modbus slave devices
Remote I/O
One of COM3 or COM4 supports I-7000 I/O modules (I-87K base + I-87K serial I/O boards or RU-87P1/2/4/8 + I-87K High Profile I/O cards) as Remote I/O. Max. 64 Remote I/O modules for one controller.
Fbus
Built-in COM3 Port to exchange data between ICP DAS's ISaGRAF PACs
SMS: Short Message Service
One of COM4 or COM5 can link to a GSM modem to support SMS. User can request data/controller by cellular phone. The controller can also send data alarms to user's cellular phone. Optional GSM modems: GTM-201-RS232 (850/900/1800/1900 GSM/GPRS External Modem).
User-defined Protocol
User can write his own protocol applied at COM1, 3, 4 ( COM5 ~ 20 if multi-serial port boards are plugged) by serial communication function blocks
Modem Link
Supports PC remotely download monitor the controller through a normal modem.
MMICON / LCD
One of COM3 or COM4 supports ICP DAS's MMICON. The MMICON is featured with a 240 x 64 dot LCD and a 4 x 4 Keyboard. User can use it to display picture, string, integer, float, and input a character, string, integer and float.
Redundant Bus7000
Two ISaGRAF controllers can link to remote I-7000 I-87K I/O modules at the same time. Only one controller is active to control these remote I/Os. If one is dead, the other one will take over the control of remote I/Os.
Battery backup SRAM
Supports up to 1024 retain variables with a S256/S512 plug in the socket of the back-plane. Data can also be stored in the S256/S512, and then PC can load these data via COM1 or COM2. PC can also download pre-defined data to the S256/S512. Optional: S256: 256 KB, S512: 512 KB