| Parameters |
| Product Description |
| Model | KIEN2032 |
| Description | Managed Industrial Ethernet Rail Switch, networking topology based, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) |
| Port Type and Quantity | 2 x 100Mbit/s, optical fiber, single/multimode, full duplex, redundant 3 x 10 /100Base-T/TX, TP cable, RJ45 Socket (shielded), auto-negotiation, auto-polarity 2 x RS232, or 2 x RS485, or 1xRS232/1xRS485 |
| More Interface |
| Power Terminal | 1 x DC power terminal, 3-core |
| RS232 interface | 1 x RJ45 socket |
| Network size - length of cable |
| Twisted pair (TP) | 100m |
| Multimode fiber | Distance: 2-5km Wavelength: 1310nm Optical power: >-20dbm |
| Singlemode fiber | Distance: 40km(60km, 80km for special requirement) Wavelength: 1310/1550nm Optical power: >-13dbm |
| Network size - cascadibility |
| Line - / star topology | Any |
| Ring structure (DT-Ring) | 50 switches (recovery time < 300ms) |
| Power requirements |
| Power input | 18V-36V DC power input |
| Power consumption | <6W |
| Performance |
| Transfer Rate | 148810pps |
| MAC Address Table Size | 8K |
| Service |
| Diagnostics | LEDs(power, link status, port rate, management status) |
| Configuration | KyvisionV2.0 |
| Other services | Prioritization (IEEE 802.1D/p), VLAN, broadcastlimiter, flow control (IEEE802.3x) |
| Redundancy |
| Redundancy functions | DT-Ring (ring structure) |
| Ambient conditions |
Operating temperature | -35°C to +75°C | | Storage/transport temperature | -45°C to +85°C |
| Relative humidity (non-condensing) | 10% to 95% |
| MTBF | 10years |
| Mechanical construction |
| Dimensions (W x H x D) | 55.4mm x 142mm x 120.5mm |
| Mounting | Din-rail, Wall-mounting |
| Protection class | IP40 |
| EMC interference immunity |
| EN 61000-4-2 electrostatic discharge (ESD) | +4 kV contact discharge, +8 kV air discharge |
| EN 61000-4-3 electromagnetic field | 10 V/m (80 - 1000 MHz) |
| EN 61000-4-4 fast transients (burst) | +2 KV power line, +1 kV data line |
| EN 61000-4-5 surge voltage | Power line: +2 kV (line/earth), +1 kV (line/line), +1 kV data line |
| EN 61000-4-6 conducted immunity | 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
| EMC emitted immunity |
| FCC CFR47 Part 15 | FCC CFR47 Part 15 Class A |
| EN 55022 | EN 55022 Class A |
| Approvals |
| Certificates | FCC, CE |