WinPAC-8xx7 Series (WP-8137/8437/8837/8147/8447/8847) is the new generation WinCE 5.0 based ISaGRAF PAC (Programmable Automation Controller) of ICP DAS. WP-8xx7 is equipped with a PXA270 CPU (520 MHz) running Windows CE 5.0 Operating System, various connectivity including 10/100 Base-TX Dual Ethernet Ports, 2 or 4 RS-232/485 ports, 1 VGA,
1 or 2 USB ports, and 1/4/8 slots for high performance Parallel-type I/O modules (High Profile I-8K series) and Serial-type I/O modules (Hot-Swap High Profile I-87K series), etc. Memories come with 128 MB SRAM, 512 KB dual battery backup SRAM, 96 or 128 MB FLASH and 1 GB microSD. For redundant supporting: Dual Watchdog Timers, redundant power inputs, dual battery backup SRAM, dual Ethernet Ports. WinPAC Series will upgrade your control system!
Options: Microsoft EVC++4.0 or VS .NET 2003/2005/2008 (VB .NET 2003/2005/2008, C# .NET 2003/2005/2008)
Web Service
Web HMI
Support Web HMI function, PC running Internet Explorer can access to the WP-8x47 via Local Ethernet or Internet or dial Modem, monitoring and control.
Security
Web HMI supports three levels user name and password protection
Power Supply
Input Range
+10 ~ +30 V DC (unregulated)
Isolated
1 kV
Redundant Power Inputs
Yes, with one power relay (1 A @ 24 VDC) for alarm
Protection
WP-8147: 1.0 A, 5 V supply to CPU and backplane; 0.6 A, 5 V supply to I/O expansion slots, total 8 W
WP-8447: 1.1 A, 5 V supply to CPU and backplane; 4.9 A, 5 V supply to I/O expansion slots, total 30 W
WP-8847: 1.2 A, 5 V supply to CPU and backplane; 4.8 A, 5 V supply to I/O expansion slots, total 30 W
Consumption
WP-8147: 7.3 W (0.3 A @ 24 V);
WP-8447: 9.1 W (0.38 A @ 24 V);
WP-8847: 9.6 W (0.4 A @ 24 V);
General Environment
Temperature
Operating: -25 ~ +75 C,
Storage : -30 ~ +85 C
Humidity
5~ 95 % RH (non-condensing )
System
CPU
CPU: PXA270, 32-bit and 520 MHz or compatible
Dual Watchdog Timers
Watchdog: Dual Watchdog Timers
RTC (Real Time Clock)
Provide seconds, minutes, hours, day of week/month, month and year, valid from 1980 to 2079
SDRAM
128 MB
Dual Battery Backup SRAM
512 KB (for 5 years data retention while power off)
FLASH
96 MB (64 MB for OS image, 31 MB for built-in Flash disk, 1 MB for registry)
Expansion Flash Memory
microSD socket with 1 GB microSD card (can support up to 16 GB compatible microSDHC card)
EEPROM
16 KB, Data retention: 40 years. 1,000,000 erase/write cycles
Rotary Switch
Yes (0~9)
DIP Switch
-
Yes (8 bits)
Yes (8 bits)
NET ID
From 1 ~ 255, User-assigned by software
Unique Serial Number
Yes,64-bit hardware unique serial number
Serial Ports
VGA Port
1 VGA port (800 x 600 resolution)
USB Port
one USB 1.1 Host ports for USB mouse, keyboard or USB drive
COM0
Internal communication with the I-87K High Profile modules in slots
COM1
RS-232 (RxD, TxD, and GND); Non-Isolated; Speed: 115200 bps max.
Link to max. 100 devices that support Standard Modbus TCP/IP Slave protocol.
Modbus RTU/ASCII Master (multi-port)
Up to 10 COM Ports (COM1~ 4 and COM5~COM14 if multi-serial port boards are plugged in Slot 0~3) can support multi-ports of Modbus RTU/ASCII Master protocol to connect to other Modbus Slave devices. (WP-8147 has no COM3 & COM4.)
Modbus RTU Slave Protocol
Up to 5 COM Ports (COM1, one of COM2/3, COM4 and COM5 ~ COM8) can support Modbus RTU Slave protocol for connecting ISaGRAF, PC/HMI/OPC Server & HMI panels. (WP-8147 has no COM3 & COM4.)
Modbus TCP/IP Slave Protocol
2 Ethernet Ports all support Modbus TCP/IP Slave protocol for connecting ISaGRAF & PC/HMI.LAN1 & LAN2 support total up to 32 connections. (If WP-8x47 uses 1 connection to connect each PC/HMI, it can connect up to 32 PC/HMI; If WP-8x47 uses 2 connections to connect each PC/HMI, it can connect up to 16 PC/HMI; ...) When one Ethernet port is broken, the other one can still connect to PC/HMI.
Web HMI Protocol
Ethernet port for connecting PC running Internet Explorer.
I-7000 & I-87K RS-485 Remote I/O
One of COM2, COM3 supports I-7000 I/O modules, I-87K base + I-87K Serial I/O boards and RU-87P1/2/4/8 + I-87K High Profile I/O boards as Remote I/O. Max. 255 pcs. of I-7000/87K Remote I/O modules for one controller. (WP-8147 has no COM3 & COM4.)
M-7000 Series Modbus I/O
Max. 10 RS-485 ports (COM1~4 & COM5~COM14 if multi-serial port boards are plugged in) can support M-7000 series Modbus I/O. Each port can connect up to 32 M-7000 Modules.
Modbus TCP/IP I/O
LAN2 supports ICP DAS Ethernet I/O : I-8KE4-MTCP and I-8KE8-MTCP listed at www.icpdas.com > FAQ > Software > ISaGRAF Ver.3 (English) FAQ-042.If LAN2 is broken, it will switch to LAN1 automatically to continuously work. (This need LAN1 & LAN2’s IP are set in the same IP domain)
FRnet I/O
Support max 8 pcs. I-8172W boards in slot 0 to 7 to connect to FRnet I/O modules, like FR-2053, FR-2057 FR-32R, FR-32P, at www.icpdas.com > FAQ > Software > ISaGRAF Ver.3 (English) FAQ-048. Each I-8172w board can connect up to 256 DI plus 256 DO channels.
Send Email
Supports mail_snd and mail_set functions to send email with one attached file via Ethernet port.
Ebus
To exchange data between ICP DAS’s ISaGRAF Ethernet controllers via Ethernet port. (LAN2 Port only)
SMS: Short Message Service
One of COM4 (or COM5 if multi-serial port board is plugged in) can link to a GSM Modem to support SMS. User can request data/control the controller by cellular phone. The controller can also send data & alarms to user’s cellular phone. Optional GSM Modems: GTM-201-RS232 (850/900/1800/1900 GSM/GPRS External Modem)
User-defined Protocol
User can write his own protocol applied at COM1~COM4 & COM5~COM14(if multi-serial port boards are plugged in) by Serial communication function blocks.
Modem_Link
WP-8x47 series does not support Modem_Link.
MMICON/LCD
COM4 or COM5(if I-8112W/8114W is found) supports ICP DAS's MMICON. The MMICON is featured with a 240 x 64 dot LCD & a 4 x 4 Keyboard to display picture, string, integer, float, & input a char, string, integer & float.
UDP Server & UDP Client
(Exchange Message &
Auto-Report)
LAN1 or LAN2 support UDP Server and UDP/IP Client protocol to send/receive message to/from PC/HMI or other devices. For example, to automatically report data to InduSoft's RXTX driver.
TCP Client
(Exchange Message &
Auto-Report)
LAN1 or LAN2 support TCP Client protocol to send/receive message to/from PC/HMI or other devices which support TCP Server protocol. For example, to automatically report data to InduSoft ‘s RXTX driver, or to connect a location camera.
New Hot-Swap and Redundant System
This redundant system has setup two “Active IP” address point to the active WP-8x47's LAN1 and LAN2 ports always. One or two or more PC/HMI/SCADA can communicate with this redundant system via one of the two given active IP. So the PC/HMI/SCADA can access to the system easily without any notice about which WP-8x47 is currently active.
Moreover, the new redundant system can integrate with the RU-87P4 and RU-87P8 expansion unit plus the I-87K high-profile I/O cards to support the hot-swap application. If the I/O card is damaged, the maintenance person just takes one good-card with same model number to hot-swap the damaged one without stopping this redundant system. Please refer to www.icpdas.com > FAQ > Software > ISaGRAF Ver.3 (English) FAQ-093.
CAN/CANopen
WP-8x47 can use its COM1,3,4 or COM5~COM14 resides at the I-8112iW/8114W/8114iW RS-232 expansion board to connect one I-7530 : the RS-232 to CAN converter to support CAN and CANopen devices and sensors. One WP-8x47 supports max.10 RS-232 ports to connect max.10 I-7530. Please refer to www.icpdas.com > FAQ > Software > ISaGRAF Ver.3 (English) FAQ-086.
Order Information
WP-8147-EN
1 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: English)
WP-8447-EN
4 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: English)
WP-8847-EN
8 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: English)
WP-8147-TC
1 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: Traditional Chinese)
WP-8447-TC
4 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: Traditional Chinese)
WP-8847-TC
8 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: Traditional Chinese)