Tabelka poniżej prezentuje parametry techniczne urządzenia. W przypadku, gdyby prezentowane w niej informacje były niekompletne lub budziły wątpliwości prosimy o kontakt mailem bądź telefonicznie z naszym działem technicznym. Dodatkowo służymy pomocą w doborze właściwego urządzenia tak, aby optymalnie spełniało wymagania Państwa projektu.
Product
specification |
Model | KIEN3024M |
Description | Economical, unmanaged Industrial Ethernet Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) |
Port Type and Quantity | 24 x 10 /100Base-T(X), TP cable, RJ45 Socket, Auto-Negotiation, auto MD/MDI-X connection |
More Interface |
Power Terminal | 1 x AC220V power terminal |
Network size - length of cable |
Twisted pair (TP) | 100m |
Multimode fiber | Distance: 2-5km Wavelength: 1310nm Optical power: >-20dbm |
Singlemode fiber | Distance: 40km(60km, 80km for special requirement) Wavelength: 1310/1550nm Optical power: >-13dbm |
Network size - cascadibility |
Line - / star topology | Any |
Power requirements |
Power input | AC 220V, DC24V, DC-48V, DC110V |
Power consumption | < 25W |
Performance |
Transfer Rate | 148810pps |
MAC Address Table Size | 8K |
Service |
Diagnostics | LEDs(power, link status, port rate,) |
Security | Port security (MAC based and IP based) |
Other services | Broadcastlimiter |
Ambient conditions |
Operating temperature | -35°C to +75°C |
Storage/transport temperature | -45°C to +85°C |
Relative humidity (non-condensing) | 10% to 95% |
MTBF | 10years |
Mechanical construction |
Dimensions (W x H x D) | 482.6mm x 44mm x 245mm |
Mounting | Rack-mounting (19′1U) |
Protection class | IP40 |
EMC interference immunity |
EN 61000-4-2 electrostatic discharge (ESD) | +4 kV contact discharge, +8 kV air discharge |
EN 61000-4-3 electromagnetic field | 10 V/m (80 - 1000 MHz) |
EN 61000-4-4 fast transients (burst) | +2 KV power line, +1 kV data line |
EN 61000-4-5 surge voltage | Power line: +2 kV (line/earth), +1 kV (line/line), +1 kV data line |
EN 61000-4-6 conducted immunity | 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
EMC emitted immunity |
FCC CFR47 Part 15 | FCC CFR47 Part 15 Class A |
EN 55022 | EN 55022 Class A |
Approvals |
Certificate | FCC, CE |